This machine is a Automatic Solder Paste Mixing Equipment.Size:390 x 390 x385
1.Professional SMT Digital has Strong mixing ability,satisfy ISO-9000 cream mixing conditions.
2. Attached red rubber fixture,can be used as red rubber claves.
3.Micro-computer digital control,easy operation.
4. SMT Solder Paste Mixing machine has strong adaptability,with all-purpose fixture,suitable for various brands of cream.
5. Multiple security protection,ensure the safe operation.
6. Operated speed:480RPM
7. Work ability: 100-1000g, put two bottles at the same time.
8.Mixing time:0.1-9.9minutes.
Stirring a variety of solder pastes such as ISO-9000, can be used as a red glue decreate.
Any details about Solder Paste Mixing machine you want to know please contact us for further more.
SMT Solder Mixer,Solder Paste Mixing Equipment,Solder Paste Mixing Machine,Solder Pasting Mixer,strong mixing ability SINGSUN ELECTRONIC SCIENCE & TECH CO.,LTD , https://www.singsunautomatics.com
First, if the steel structure weighing platform is not qualified, if the thickness of the panel is not enough or the strength of the main beam is not enough during the production of the pound body, the pound body will be deformed and the force of the sensor will be generated. In particular, negative numbers are often generated when the vehicle is weighed down. Then the ground scale cannot be called normal. Unreasonable structural designs and design flaws can also result in inaccurate scales. Structural inaccurate, generally unable to repair, it is recommended to replace.
Second, the basic design and construction did not meet the requirements. The foundation is not embedded steel embedded parts, no steel. If multiple sensors are not in the same level during use, then the platform scale is definitely not accurate. Foundations without embedded parts can also cause sensor damage. Therefore, we suggest that the ground loader be embedded.
Second, the quality of sensors and meters is not good. The floor scale consists of a meter, a pound body, and a sensor (also called a sensor). If the accuracy of the instrument used is not high, and the electromagnetic anti-jamming capability is not good, coupled with the use of inferior sensors, the pound body adopts inferior steel or jerry-building materials. The position of the loadometer when carrying the weight is different, and the result is not the same. The sensor is the core element responsible for weighing. Whether it is good or bad is directly related to whether the weighing result is accurate, so the quality of the selected sensor is of great importance. Hardware is not allowed. The solution is to replace it. A better accessory can be solved. Poor sensor quality occupies about 50% of ground fault rate.
Third, the aging of the sensor: In general: the life of the sensor is about 8 years, if the long-term load, high frequency use, the life of the sensor will be shortened. (eg cement plants, power plants). Therefore, the aging of the sensor will also result in inaccurate weighing.
Fourth, man-made damage, rat bites, flooding. The system suffers from high voltage. Lightning or lightning strikes can cause system damage. In addition, hot-plugging (plugging the meter plugged in) can also cause system damage. Weighing is not allowed.
In short: To be accurate on the floor scale, please purchase the brand floor scale.
Weighing electronic scales is often not allowed to be an old problem that has plagued many customers. There are four reasons for this, especially when the weighbridges are used in some industries. Due to the high price of the products, the losses caused by the weighbridge errors are increasing. Constantly repairing or replacing the weighbridge has become a helpless choice for customers. What causes the ground penal scales?